top of page

Clarity Plus

A cutting-edge digital PCR solution designed to meet your absolute quantification needs. Featuring more than 40,000 partitions per reaction on a high-density chip to deliver exceptional resolution, sensitivity, and dynamic range for RNA and DNA quantification.

Overview

The Clarity Plus system facilitates efficient and reliable sample partitioning on our proprietary high-density chips. It ensures high resolution and accurate nucleic acid quantification with low limit of detection and wide dynamic range. It incorporates a 6-colour detection platform, enabling multiplexed quantification in each reaction chip. This marks a significant advancement over the original Clarity system, offering enhanced capabilities while maintaining the easy workflow and high-throughput features of its predecessor. With these improvements, the Clarity Plus stands out as one of the more advanced digital PCR systems available today. 

Clarity Plus in lab (BW hi-res).png

40K partitions

 

​Samples are subdivided into more than 40,000 partitions per reaction. Single molecule analysis of these partitions provide higher sensitivity and better accuracy for quantification of DNA/RNA over a wider dynamic range of concentrations.

6 colour detection

 

Absolute quantification of up to 6 targets can be achieved without the need for references and standards. Better quality data can now be attained using fewer reactions and at lower costs. It is now possible to perform high multiplexed digital PCR

96 reactions

 

Sample throughput is not compromised. Run up to 96 reactions to analyze hundreds of different targets in a single digital PCR run while generating millions of data points. Such performance opens up more applications for digital PCR like never before.

Tube-strips

The tube-strips are the core component of the entire system, and they are far from ordinary. Each tube contains a high-density chip, embedded within the strip. When a sample is added, it is delivered over the top surface of the chip, where capillary forces rapidly draw the sample into the chip. This process subdivides the sample into more than 40,000 partitions per chip. Each tube-strip can hold up to 8 samples, offering remarkable throughput. There is no need for complex microfluidics—analysis can be performed on a single chip with 40,000 partitions, or multiple chips can be combined to achieve over 320,000 partitions within a single tube-strip. The partitions remain securely inside the tube throughout the entire digital PCR process, delivering extraordinary performance and unmatched flexibility

Tube strips multiple 4.jpg

Features

Superior Specifications

Absolute Quantification

Detects and measures nucleic acid copies with high precision and sensitivity

Closed Tube Format

Prevents cross contamination among reactions

Chip-based Partitioning

Stable partitions minimises sample loss

Minimal Sample Loss

Proprietary method minimises sample loss and increase accuracy

Easy Workflow

Unique chip-in-a-tube design simplifies digital PCR workflow

Flexible

Compatible with conventional thermal cyclers; Optimised for both probe-based and EvaGreen® assays

Workflow

Workflow image.JPG

Load sample, partition and seal

Using the Auto Loader, 8 samples at a time are loaded and pushed into the chips. Each is then subdivided into more than 40,000 high density partitions. There is minimal sample loss and no dead volume.​The Sealing Enhancer increases the separation between adjacent partitions. Addition of the Sealing Fluid seals and discretizes the partitions.

Thermal cycle

Tube-strips are placed onto a deep 96-well thermal cycler for amplification. Up to 12 tube-strips (or 96 reactions) can be run each time. There is also the flexibility to run fewer strips

Read

After amplification, tube-strips are placed into the Reader for endpoint signal readout. Multiplexed analysis is achieved with the 6 detection channels that can detect several targets in each chip.

Analyze

Powered by AI, the software uses a proprietary method to identify every single partition from each chip. Following that,  it classifies each partition into positive and negative based on their intensities. With that information and using Poisson statistics, highly multiplex absolute quantification is achieved on the Clarity Plus.

Clarity Plus Workflow Video

Technical Specifications

Reaction volume
15 ul
Partitions per reaction
40,000 to 45,000
Partition volume
0.3 nL
Reactions per strip
8
Tube capacity
0.2 mL
Sample loss
< 5 %
Thermal cycling
Deep well thermal cycler for 0.2 mL tubes with adjustable ramp rates
Reader throughput
32
Reaction chemistry
TaqMan® and SYBR® Green/EvaGreen®
Detector
CMOS
Detection channels
6-colors: FAM™, HEX™, ATTO™ 550, Texas Red®, Cy5™, and Cy5.5™
Detection mode
End point
Light source
High power LED
Reader interface
USB and Ethernet

Ordering Information

Product                            

Contents

Cat Number

Clarity Plus digital PCR system

Clarity Auto-Loader; Clarity Sealing Enhancer; Clarity Plus Reader; Clarity Plus software

20002

© 2024 by JN Medsys

bottom of page